CALL US
0086-371-60922096

2 5 line pump for placing slab on grade concrete

The Slab on Grade Installation | | DIY Radiant Floor

Introduction A slab on grade is defined as any concrete slab poured over excavated soil. From a radiant heating perspective, it doesn't matter if the slab is actually "at grade" or is poured several feet below grade as part of a full foundation. Check out our video How to Install Radiant Floor Heat Tubing in […]

Learn More

Concrete Pumping - How to Pump Cement - Concrete Network

Concrete Line Pumps - Concrete Trailer Pumps, Concrete

Learn More

Mix Design and Pumped Concrete - Civil Engineering Portal

Mar 01, 2010 · Generally speaking, the maximum slump for a pumped mix is about 6 inches. The ideal concrete mix for pumping typically contains air-entraining agents, a little extra sand (compared with a standard concrete mix), often some fly ash, and a well-graded aggregate blend. To make the concrete easier to pump and place as it comes out of the hose, many

Learn More

Lonsdaleoncrete Floors, INC. - Lonsdale Concrete

If you are unsure which specific type of concrete pump is best for your project, please contact us for a site inspection or evaluation, free of charge. Make your next project a success by contacting AJ Concrete Pumping Service at 1-800-783-8185 to schedule a free site visit and project estimate.

Learn More

(PDF) Chapter 5. Concrete Design and Construction Details

The concrete slab thickness is determined based on estimated wheel and axle loadings, and soil subgrade design factors. Table 5.4 shows the thickness of concrete needed for various axle loads. Reinforcing schedules for a mixing and loading pad floor slab on grade with one layer of reinforcing are shown in Tables 5.5(alternate) and 5.6.

Learn More

SLAB ON GRADE REINFORCING DESIGN - PDHonline.com

Concrete slabs on grade are a very common type of concrete construction. Floor slabs can range from a simple residential basement slab to a heavy-duty industrial floor. However, no matter how basic or complex the floor is, the construction method is similar and includes; preparing the sub-grade and sub-base, placing the reinforcement and

Learn More

Best Mix for Pumped Concrete | JLC Online

Mar 01, 2010 · Generally speaking, the maximum slump for a pumped mix is about 6 inches. The ideal concrete mix for pumping typically contains air-entraining agents, a little extra sand (compared with a standard concrete mix), often some fly ash, and a well-graded aggregate blend. To make the concrete easier to pump and place as it comes out of the hose, many

Learn More

Methods of Transportation of Concrete - Dumpers, Trucks

Feb 09, 2017 · Transporting the concrete mix is defined as the transferring of concrete from the mixing plant to the construction site. The main objective in transporting concrete is to ensure that the water-cement ratio, slump or consistency, air content, and homogeneity are not modified from their intended states. Concrete produced from a mixer is required to be transported to the

Learn More

(251) 216-9995 - Concrete Pumping Company, Mobile, AL

A concrete line pump is ideal for placing concrete footings, as often the foundation must be placed located several feet lower than grade or below the frost line. With a concrete line pump truck, there is no need for additional equipment or bulldozers to provide access for ready-mix trucks.

Learn More

Concrete Line Pumps - Concrete Trailer Pumps, Concrete

The concrete pump hose can range in diameter from 2 inches to 5 inches and are usually 10 feet long. The larger diameter hoses 3, 4, and 5 inch are typically used for pumping concrete and the 2 inch pump hose is mostly used for pumping grout and shotcrete. The concrete pump hoses are connected together with concrete pump clamps reaching horizontal lengths from 20 to 1500 feet.

Learn More

Small Line Concrete Pumps | Cross Enterprises Concrete

Theor. Concrete Output: 182 cu yds/h 139 cu m/h: 183 cu yds/h 140 cu m/h: Max. Pressure on Concrete: 1233 psi 85 bar: 1233 psi 85 bar: Max. Strokes Per Minute: 28: 38: Max. Aggregate size: 2.5 in 63.5 mm: 2.5 in 63.5 mm: Material Cylinder Diameter: 9 in 230 mm: 8 in 200 mm: Material Cylinder Stroke: 79 in 2000 mm: 79 in 2000 mm: Differential

Learn More

Specification Limits on Slab-on-Grade Placement Size | For

May 13, 2013 · Specification Limits on Slab-on-Grade Placement Size. Construction schedules and contractor economics typically require concrete placements of 10,000 to 20,000 square feet or from 30,000 to 50,000

Learn More

Engineering Standards Manual: Standard Drawings & Details

Sep 30, 2004 · Housekeeping Pad to Existing Slab Anchorage 03/08/18 NOTE: If the MCC is "unimportant (i.e., Ip = 1.0 per ASCE 7)" and being installed as part of a new- or existing-building project in which the seismic design of the building is based on SDC C, then the MCC is seismically exempt (per ASCE 7 para. 13.1.4) and compliance with the Std. Detail

Learn More

Design of Anchor Reinforcement in Concrete Pedestals

2.5 times the factored design load, where 2.5 is an overstrength factor. 4. When reinforcement is used to restraint concrete breakout, the overall anchorage design should ensure that there is sufficient strength corresponding to the three other failure modes described in the Introduction (pullout failure, side-face

Learn More

Chapter 5. Concrete Design and Construction Details

Best Mix for Pumped Concrete | JLC Online

Learn More

2.5" line pump for placing slab on grade concrete

The concrete spec'd was 4500 psi, max w/c ratio 0.45, max coarse aggregate size 1" (but 3/4" is commonly used in mix design around here), air entrainment 4.5% or 5% plus/minus 1.5% for 1" or 3/4" max aggregate size respectively, and max slump of 5". The contractor wants to use a 2.5" diameter line pump to place the concrete, and has submitted an alternate mix design for the line pump with 3/8" max …

Learn More

Placement of welded wire reinforcement (WWR) in a slab-on

The concrete slab thickness is determined based on estimated wheel and axle loadings, and soil subgrade design factors. Table 5.4 shows the thickness of concrete needed for various axle loads. Reinforcing schedules for a mixing and loading pad floor slab on grade with one layer of reinforcing are shown in Tables 5.5(alternate) and 5.6.

Learn More

HoseHog From: Somero Enterprises | For Construction Pros

Jun 19, 2007 · Somero Enterprises. Removes the need to drag concrete hose on elevated deck or slab on grade. 13-hp engine moves 3-, 4- or 5-in. hose. Use multiple units on long hose lengths. Decreases line …

Learn More

The Construction and Design of Concrete Slabs on Grade

Concrete Line Pumps - Concrete Trailer Pumps, Concrete

Learn More

ENGINEERING AND DESIGN

DEPARTMENT OF THE ARMY EM Kefid04 . U.S. Army Corps of Engineers CECW-CE Washington, DC 20314-1000 Manual . No. Kefid04 30 November 2016

Learn More